Magnetic particles Testing (MT) allows for quick and reliable detection of any surface defects in ferromagnetic materials, caused by cracks, heterogeneous structure, foreign insertations, material discontinuities.
This method is applied when detecting flaws at (the so-called "open flaws") or near ("closed flaws") the surface of the test piece. It may be used at elements with thin galvanic coatings.
The test system FLUORESCENCE (magnetic particle suspension fluorescent) - the test surface should be examined using the ultra-violet light from UV-lamps.
We use agents manufactured by DIFFU-THERM which fulfill all requirements of the ASME-Code, Section V, Article 6, DIN 54152 part 2, ASME E 165 and are regularly tested according to the requirements of ASME D 808-63 and ASTM D 129-64.
National test certificates as well as certificates issued by the manufacturer are presented for all products.